• Product Description

    We know working in electrical boxes jammed with wires can be challenging when you’re trying to find a safe metallic contact point. Now, with Fluke’s T6-600 or T6-1000 with integrated FieldSense technology, you can quickly and easily take measurements by sliding the open fork over a conductor to see the voltage level without the need for test leads.*

    Features

    Be safer: Measure voltage to 1000 V ac through the open fork, without test leads.

    Be faster: No need to open covers or remove wire nuts.

    Be more efficient: Simultaneously measure voltage and current.

    Be everywhere: 17.8 mm open fork is widest in the industry; measure up to 200 A on 4/0 wires (120 mm2).

    Go beyond simple detection. Actually measure ac voltage and current values without test leads

    FieldSense technology for ac voltage, current and frequency measurement without making electrical contact to live voltage*

    Simultaneous voltage and current display – shows all power supply measurements at a glance for efficient trouble shooting

    1 to 1000 V ac or dc (T6-1000)

    0 to 200 A ac

    True-rms voltage and current

    Resistance 1 Ω to 100 kΩ

    Frequency measurement 45 Hz to 66 Hz

    Works with wires up to AWG 4/0 (120 mm2) with a 17.8 mm jaw opening

    HOLD button temporarily freezes the reading for easy viewing

    Easy to read display with backlight

    Accepts optional Fluke TPAK Magnetic Meter Hanger for convenient operation

    Standard two-year warranty; extendable to 4 years through product registration within 45 days of purchase+

    What Is Included:

    Attached test leads with removable 4 mm probe caps

    User documentation

    Item Specification

    Calibration 1-year calibration cycle
    Dimensions 61.1 x 259.3 x 43.8 mm
    Jaw opening 17.8 mm
    Weight 0.35 kg (0.78 lb)
    Temperature Operating Storage -10 °C to +50 °C (14 °F to 122 °F)
    -30 °C to +60 °C (-22 °F to +140 °F)
    Altitude Operating Storage 2,000 m (6,562 feet)
    10,000 m (32,808 feet)
    Relative Humidity 0% to 90%, 5 °C to 30 °C (41 °F to 86 °F)
    0% to 75%, 30°C to 40 °C (86 °F to 104 °F)
    0% to 45%, 40°C to 50 °C (104 °F to 122 °F)
    Battery Type and Life 2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense
    Temperature coefficient 0.1 x (specified accuracy) / °C for <18°C or >28 °C
    (< 64.4 °F or > 82.4 °F)
    Safety IEC/EN 61010-1: Pollution Degree 2
    Electromagnetic Environment IEC/EN 61326-1: Portable

    Additional Details

    Type Voltage Testers & Proving Units