• Product Description

    The PAT150R can be re-charged with NiMH batteries fitted.

    The PAT100 series of hand-held portable appliance testers enables simple, fast safety testing in all environments including offices, shops and business units. Its tough, reliable functionality is ideally suited for training organisations with high turnover, intensive courses.

    With rubber armoured cases and hardened, scratch-proof glass, the PAT100s are exceptionally tough instruments. Battery powered operation makes the PAT100s perfect for those locations where an electrical supply is not available, inconvenient or unsafe, especially building sites and warehouses. The PAT100 series conforms to all UK and European requirements for electrical safety testing.

    Please press the link below for demonstration video

    https://youtu.be/SvQ4WfedouA?t=3m8s

    Features

    Simple tick or cross, pass or fail indication plus measurement

    Battery powered with rechargeable options

    Safe 250 V insulation and leakage test for surge-protected and IT equipment

    Testing portable and fixed electrical equipment

    Substitute leakage testing

    10 mA and 30 mA portable RCD lead testing (PAT150)

    Adjustable PASS test limits and mains

    powered leakage testing (PAT150)

    Tough, rubber armour with built-in front cover and hardened scratch-proof disp

    The PAT150 has additional tests available for testing portable

    RCDs (PRCDs) of 10 mA and 30 mA.

    Separate tests for continuity, insulation, mains powered leakage testing and SELV measurements can be made using the Quick Test (QT) button.

    Test group pass limits and test duration can be configured by the user.

    Bond lead resistance can be nulled to reduce measurement errors.

    Live circuit measurement is available for testing the mains supply and socket polarity or electrical circuit voltage to 300 V ac.

    Can be used for testing fixed appliances.

    What Is Included:

    Megger PAT150 PAT Tester

    Continuity/Earth Bond Lead

    SELV/Mains Voltage Test Lead

    Extension Lead Adapter

    Mains Plug Test Lead

    Carry Case

    Item Specification

    Environmental Condition
    Operating ambient 20 °C
    Humidity 45% rh ± 20 points
    Continuity Test
    st voltage Compliance voltage: +4 V dc, -0% +1-% (open circuit), Test current Bi-directional +200 mA, -0 % + 50 mA (into 2 Ω load)
    Continuity accuracy Resistance ± 5% ± 3 digits (0 to 19.99 Ω)
    Resolution Resistance 10 mΩ
    Display range 0.01 to 19.99 Ω
    Continuity test nulling up to 9.99 Ω
    Test time User selectable from 2 s to 20 s or selected during test to 180 s
    Insulation Test
    Insulation test 250 V dc -0% +25% open circuit, 500 V dc -0% +25% open circuit, ≥ 500 V 0% dc across 0.5 MΩ load
    Short circuit/charge current < 2mA dc
    Insulation accuracy ± 3% ± 10 digits (0 to 19.99 MΩ)
    Resolution 0.01 mA
    Display range 0.10 MΩ to 99.99 MΩ
    Test duration User selectable from 2 s to 20 s or selected during test to 180 s
    Substitute Leakage Test
    Leakage current Accuracy ± 5% ± 3 digits
    Test frequency Nominal mains frequency 50 Hz
    Test voltage < 50V ac
    Resolution 0.01 mA
    Display range 0.10 to 19.99 mA
    Test duration 0.01 mA
    Display range User selectable from 2 s to 5 s, Reading corrected to 230 V AC
    Differential Leakage Current
    Test voltage Nominal supply voltage 230 V ac
    Test frequency Nominal mains frequency 50 Hz
    Test accuracy ± 5% ± 3 digits ± 3 uA/A
    Resolution 0.01 mA
    Display range 0.10 to 19.99 mA
    Test duration User selectable from 2 s to 5 s
    Touch Current Test
    Test voltage Nominal mains 230 V ac
    Test frequency Nominal mains 50 Hz
    Test accuracy ± 5% ± 3 digits
    Resolution 0.01 mA
    Display range 0.10 to 3.99 mA
    Test duration User selectable from 2 s to 5 s
    SELV Device Test
    Test voltage 0 to 300 V ac
    Test accuracy ± 3% ± 3 digits
    Resolution 0.1 V ac
    Display range 0.1 to 300 V ac
    Extension Lead Test
    Test voltage  5 V
    Polarity Lead OK Live/neutral shorted, Live/neutral reversed, Live/neutral open circuit 
    Extension Portable RCD Test
    Test voltage Nominal mains 230 V
    Test frequency 50 Hz
    Test current accuracy +2 % to +8 % (1 x I, 5 x I)
    Test accuracy Trip time ± 1 % ± 1 ms
    Resolution Trip time 0.01 ms
    Display range 0 to 200 ms (1 x I), 0 to 40 ms (5 x I)
    Main Supply Test
    Frequency measurement range 50 Hz
    Test voltage 40 to 300 V ac
    Test accuracy ± 3% ± 3 digits
    Resolution 0.1 V ac
    Display range 40 to 300 V ac
    Circuit Test (Carried out automatically, not available to user)
    Test voltage 5 V
    Test frequency Nominal mains 50 Hz
    Test current <100mA short-circuit
    Safety Instrument designed to IEC 61010-1: 2012
    Test leads designed to IEC 61010-031: 2005
    PAT150 300 V to Earth Category II
    Mains fuse protection to 250 V rms ac
    EMC Design to meet IEC 61326-1: 2012 and IEC 61326-2-2: 2012.
    User replaceable fuse 13 A fused mains plug (PAT150-UK only),
    One F 100 mA 250 V 5x20 mm HBC
    Operating temperature 0 °C to +40 °C
    Storage temperature -20 °C to +60 °C
    Humidity 90 % rh @ +10 °C to +30 °C,
    75 % rh @ +10 °C to +60 °C
    Operating altitude up to 2,000m
    IP rating IP40 (with front cover closed)
    Mechanical
    Battery life Over 1000 full Class 1 tests using 3400 mAh Alkaline battery
    Battery type eight AA LR6 cells, 12 V dc (Alkaline cells), 9.6 V dc (NiMH cells)

    Additional Details

    Type PAT Tester